1.
Rev Sci Instrum ; 95(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38236087

RESUMO

We present the development of an experimental platform that can collect four frames of x-ray diffraction data along a single line of sight during laser-driven, dynamic-compression experiments at the National Ignition Facility. The platform is comprised of a diagnostic imager built around ultrafast sensors with a 2-ns integration time, a custom target assembly that serves also to shield the imager, and a 10-ns duration, quasi-monochromatic x-ray source produced by laser-generated plasma. We demonstrate the performance with diffraction data for Pb ramp compressed to 150 GPa and illuminated by a Ge x-ray source that produces ∼7 × 1011, 10.25-keV photons/ns at the 400 µm diameter sample.

2.
Rev Sci Instrum ; 94(12)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38088778

RESUMO

Nanosecond-gated hybrid complementary metal-oxide semiconductor imaging sensors are a powerful tool for temporally gated and spatially resolved measurements in high energy density science, including inertial confinement fusion, and in laser diagnostics. However, a significant oscillating background excited by photocurrent has been observed in image sequences during testing and in experiments at the National Ignition Facility (NIF). Characterization measurements and simulation results are used to explain the oscillations as the convolution of the pixel-level sensor response with a sensor-wide RLC circuit ringing. Data correction techniques are discussed for NIF diagnostics, and for diagnostics where these techniques cannot be used, a proof-of-principle image correction algorithm is presented.

3.
Nat Commun ; 14(1): 7046, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37949859

RESUMO

Large laser facilities have recently enabled material characterization at the pressures of Earth and Super-Earth cores. However, the temperature of the compressed materials has been largely unknown, or solely relied on models and simulations, due to lack of diagnostics under these challenging conditions. Here, we report on temperature, density, pressure, and local structure of copper determined from extended x-ray absorption fine structure and velocimetry up to 1 Terapascal. These results nearly double the highest pressure at which extended x-ray absorption fine structure has been reported in any material. In this work, the copper temperature is unexpectedly found to be much higher than predicted when adjacent to diamond layer(s), demonstrating the important influence of the sample environment on the thermal state of materials; this effect may introduce additional temperature uncertainties in some previous experiments using diamond and provides new guidance for future experimental design.

4.
Phys Rev E ; 108(3-2): 035202, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37849193

RESUMO

Strong shocks are essential components in many high-energy-density environments such as inertial confinement fusion implosions. However, the experimental measurements of the spatial structures of such shocks are sparse. In this paper, the soft x-ray emission of a shock front in a helium gas mixture (90% helium, 10% neon) and a pure neon gas was spatially resolved using an imaging spectrometer. We observe that the shock width in the helium mixture gas is about twice as large as in the pure neon gas. Moreover, they exhibit different precursor layers, where electron temperature greatly exceeds ion temperature, extending for more than ∼350µm with the helium gas mixture but less than 30µm in the pure neon. At the shock front, calculations show that the electrons are strongly collisional with mean-free path two orders of magnitude shorter than the characteristic length of the shock. However, the helium ions can reach a kinetic regime as a consequence of their mean-free path being comparable to the scale of the shock. A radiation-hydrodynamic simulation demonstrates the impact of thermal conduction on the formation of the precursors with charge state, Z, playing a major role in heat flow and the precursor formation in both the helium mixture and the pure neon gases. Particle-in-cell simulations are also performed to study the ion kinetic effects on the formation of the observed precursors. A group of fast-streaming ions is observed leading the shock only in the helium gas mixture. Both effects explain the longer precursor layer in the helium shock.

6.
Rev Sci Instrum ; 94(3): 033511, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37012804

RESUMO

High-power, short-pulse laser-driven fast electrons can rapidly heat and ionize a high-density target before it hydrodynamically expands. The transport of such electrons within a solid target has been studied using two-dimensional (2D) imaging of electron-induced Kα radiation. However, it is currently limited to no or picosecond scale temporal resolutions. Here, we demonstrate femtosecond time-resolved 2D imaging of fast electron transport in a solid copper foil using the SACLA x-ray free electron laser (XFEL). An unfocused collimated x-ray beam produced transmission images with sub-micron and ∼10 fs resolutions. The XFEL beam, tuned to its photon energy slightly above the Cu K-edge, enabled 2D imaging of transmission changes induced by electron isochoric heating. Time-resolved measurements obtained by varying the time delay between the x-ray probe and the optical laser show that the signature of the electron-heated region expands at ∼25% of the speed of light in a picosecond duration. Time-integrated Cu Kα images support the electron energy and propagation distance observed with the transmission imaging. The x-ray near-edge transmission imaging with a tunable XFEL beam could be broadly applicable for imaging isochorically heated targets by laser-driven relativistic electrons, energetic protons, or an intense x-ray beam.

7.
Rev Sci Instrum ; 94(1): 013104, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36725556

RESUMO

An x-ray Fresnel diffractive radiography platform was designed for use at the National Ignition Facility. It will enable measurements of micron-scale changes in the density gradients across an interface between isochorically heated warm dense matter materials, the evolution of which is driven primarily through thermal conductivity and mutual diffusion. We use 4.75 keV Ti K-shell x-ray emission to heat a 1000 µm diameter plastic cylinder, with a central 30 µm diameter channel filled with liquid D2, up to 8 eV. This leads to a cylindrical implosion of the liquid D2 column, compressing it to ∼2.3 g/cm3. After pressure equilibration, the location of the D2/plastic interface remains steady for several nanoseconds, which enables us to track density gradient changes across the material interface with high precision. For radiography, we use Cu He-α x rays at 8.3 keV. Using a slit aperture of only 1 µm width increases the spatial coherence of the source, giving rise to significant diffraction features in the radiography signal, in addition to the refraction enhancement, which further increases its sensitivity to density scale length changes at the D2/plastic interface.

8.
Rev Sci Instrum ; 94(1): 013101, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36725595

RESUMO

Two extended x-ray absorption fine structure flat crystal x-ray spectrometers (EFX's) were designed and built for high-resolution x-ray spectroscopy over a large energy range with flexible, on-shot energy dispersion calibration capabilities. The EFX uses a flat silicon [111] crystal in the reflection geometry as the energy dispersive optic covering the energy range of 6.3-11.4 keV and achieving a spectral resolution of 4.5 eV with a source size of 50 µm at 7.2 keV. A shot-to-shot configurable calibration filter pack and Bayesian inference routine were used to constrain the energy dispersion relation to within ±3 eV. The EFX was primarily designed for x-ray absorption fine structure (XAFS) spectroscopy and provides significant improvement to the Laboratory for Laser Energetics' OMEGA-60 XAFS experimental platform. The EFX is capable of performing extended XAFS measurements of multiple absorption edges simultaneously on metal alloys and x-ray absorption near-edge spectroscopy to measure the electron structure of compressed 3d transition metals.

10.
Rev Sci Instrum ; 93(10): 103548, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36319320

RESUMO

A new class of crystal shapes has been developed for x-ray spectroscopy of point-like or small (a few mm) emission sources. These optics allow for dramatic improvement in both achievable energy resolution and total throughput of the spectrometer as compared with traditional designs. This class of crystal shapes, collectively referred to as the Variable-Radii Spiral (VR-Spiral), utilize crystal shapes in which both the major and minor radii are variable. A crystal using this novel VR-Spiral shape has now been fabricated for high-resolution Extended X-ray Absorption Fine Structure (EXAFS) experiments targeting the Pb-L3 (13.0 keV) absorption edge at the National Ignition Facility. The performance of this crystal has been characterized in the laboratory using a microfocus x-ray source, showing that high-resolution high-throughput EXAFS spectra can be acquired using this geometry. Importantly, these successful tests show that the complex three-dimensional crystal shape is manufacturable with the required precision needed to realize the expected performance of better than 5 eV energy resolution while using a 30 mm high crystal. An improved generalized mathematical form for VR-Spiral shapes is also presented allowing improved optimization as compared to the first sinusoidal-spiral based design. This new formulation allows VR-Spiral spectrometers to be designed at any magnification with optimized energy resolution at all energies within the spectrometer bandwidth.

11.
Zhonghua Yi Xue Za Zhi ; 102(39): 3134-3142, 2022 Oct 25.
Artigo em Chinês | MEDLINE | ID: mdl-36274598

RESUMO

Objective: To observe the lipid metabolism characteristics of tumor-associated macrophages (TAM) after malignant transformation in the glioma micro-environment, and analyze the biological phenotype changes and regulatory mechanisms after inhibiting the lipid metabolism remodeling. Methods: Twelve male Balb/c mice of 6-8 weeks were used in the study. Macrophages (Mφ) were derived from mouse bone marrow, and malignantly transformed macrophages (tMφ1 and tMφ2) were cloned from the model of glioma stem cell (GSC) through interaction with Mφ in vivo and in vitro. Intracellular lipid droplet formation and cellular cholesterol content were measured respectively in Mφ, tMφ1 and tMφ2. qRT-PCR was performed to detect the genes expression level related with lipid metabolism, including sterol regulatory element binding protein (SREBP), fatty acid synthase (FASN), and 3-hydroxy-3-methylglutarate monoacyl coenzyme A reductase (HMG-CoA). Simvastatin (SIM) was used to analyze the proliferation, immigration and invasiveness ability in tMφ1 and tMφ2 after inhibition of the lipid metabolism. Differential expression profiles of miRNAs after SIM treatment were constructed in t-Mφ1 and bio-informatics analysis was screened and verified for miR449a and its target gene sorting micro-tubule connectin 17 (SNX17) associated with lipid metabolism remodeling. The effect on SNX17 by up-regulated miR-449a were analyzed by qRT-PCR and Western blot, meanwhile, the biological phenotype and cholesterol content were observed after up-regulation of miR449a. Low-density lipoprotein receptor (LDLR) protein levels after SNX17 knockdown and intracellular cholesterol content after LDLR knockdown were detected respectively. Results: The numbers of intracellular lipid droplet formation in tMφ1 and tMφ2 were more than that in Mφ (P<0.001). Likewise, the relative contents of cholesterol (3.89±0.68 and 3.56±0.53), SREBP (4.78±0.60 and 2.84±0.41), FASN (4.65±0.70 and 3.01±0.45), and HMG-CoA (5.74±0.55 and 2.97±0.34) were significantly higher in tMφ1 and tMφ2 than those of Mφ (1.01 wel, 1.02 wel and 0.99 wel, respectively) (all P<0.001). The proliferation rates of tMφ1 and tMφ2 decreased from (47.06±5.88) % and (45.29±5.64)% to (23.53±4.70)% and (18.74±5.76)%, respectively after treatment with SIM (both P<0.05). The numbers of migrated cells decreased from 1 025±138 and 350±47 to 205±63 and 99±25, respectively (both P<0.001). And the numbers of invasiveness cells decreased from 919±45 and 527±34 to 220±23 and 114±21, respectively (both P<0.001). While the relative intracellular cholesterol content decreased to 0.52±0.08 and 0.58±0.07 (both P<0.05), respectively. MiR-449a was screened from tMφ1 by SIM, and the target gene was analyzed and verified to be SNX17. SNX17 expression was down-regulated, and the proliferation rate, the number of migration and invasiveness was significantly decreased after miR-449a over-expression (all P<0.05). Low-density lipoprotein receptor (LDLR) expression was down-regulated after knock-down of SNX17, while the cholesterol content was decreased after knock-down of LDLR in tMφ1 and tMφ2 (all P<0.05). Conclusions: Malignantly transformed TAMs undergo lipid metabolism remodeling characterized with enhanced lipid metabolism. MiR-449a regulates the LDLR by targeting SNX17, thereby affecting the lipid metabolism of malignantly transformed macrophages, and subsequently inhibiting its proliferation, migration, and invasion ability. Precise intervention with miR-449a/SNX17/LDLR axis could provide an experimental basis for reversing its tumor-promoting micro-environment remodeled by GSC through metabolic intervention.


Assuntos
Glioma , MicroRNAs , Camundongos , Animais , Masculino , Metabolismo dos Lipídeos/genética , Conectina/metabolismo , Proteína de Ligação a Elemento Regulador de Esterol 1/genética , Proteína de Ligação a Elemento Regulador de Esterol 1/metabolismo , Colesterol , Transformação Celular Neoplásica , MicroRNAs/genética , Macrófagos/metabolismo , Ácido Graxo Sintases/metabolismo , Sinvastatina , Oxirredutases/metabolismo , Lipoproteínas LDL/metabolismo , Coenzima A/metabolismo , Microambiente Tumoral
12.
Rev Sci Instrum ; 93(9): 093502, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182497

RESUMO

Image formation by Fresnel diffraction utilizes both absorption and phase-contrast to measure electron density profiles. The low spatial and spectral coherence requirements allow the technique to be performed with a laser-produced x-ray source coupled with a narrow slit. This makes it an excellent candidate for probing interfaces between materials at extreme conditions, which can only be generated at large-scale laser or pulsed power facilities. Here, we present the results from a proof-of-principle experiment demonstrating an effective ∼2 µm laser-generated source at the OMEGA Laser Facility. This was achieved using slits of 1 × 30 µm2 and 2 × 40 µm2 geometry, which were milled into 30 µm thick Ta plates. Combining these slits with a vanadium He-like 5.2 keV source created a 1D imaging system capable of micrometer-scale resolution. The principal obstacles to achieving an effective 1 µm source are the slit tilt and taper-where the use of a tapered slit is necessary to increase the alignment tolerance. We demonstrate an effective source size by imaging a 2 ± 0.2 µm radius tungsten wire.

13.
Phys Rev E ; 105(5-2): 055206, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35706166

RESUMO

Laser-accelerated proton beams are applicable to several research areas within high-energy density science, including warm dense matter generation, proton radiography, and inertial confinement fusion, which all involve transport of the beam through matter. We report on experimental measurements of intense proton beam transport through plastic foam blocks. The intense proton beam was accelerated by the 10ps, 700J OMEGA EP laser irradiating a curved foil target, and focused by an attached hollow cone. The protons then entered the foam block of density 0.38g/cm^{3} and thickness 0.55 or 1.00mm. At the rear of the foam block, a Cu layer revealed the cross section of the intense beam via proton- and hot electron-induced Cu-K_{α} emission. Images of x-ray emission show a bright spot on the rear Cu film indicative of a forward-directed beam without major breakup. 2D fluid-PIC simulations of the transport were conducted using a unique multi-injection source model incorporating energy-dependent beam divergence. Along with postprocessed calculations of the Cu-K_{α} emission profile, simulations showed that protons retain their ballistic transport through the foam and are able to heat the foam up to several keV in temperature. The total experimental emission profile for the 1.0mm foam agrees qualitatively with the simulated profile, suggesting that the protons indeed retain their beamlike qualities.

14.
Appl Opt ; 61(8): 1987-1993, 2022 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-35297891

RESUMO

Warm dense matter is a region of phase space that is of high interest to multiple scientific communities ranging from astrophysics to inertial confinement fusion. Further understanding of the conditions and properties of this complex state of matter necessitates experimental benchmarking of the current theoretical models. We discuss the development of an x-ray radiography platform designed to measure warm dense matter transport properties at large laser facilities such as the OMEGA Laser Facility. Our platform, Fresnel diffractive radiography, allows for high spatial resolution imaging of isochorically heated targets, resulting in notable diffractive effects at sharp density gradients that are influenced by transport properties such as thermal conductivity. We discuss initial results, highlighting the capabilities of the platform in measuring diffractive features with micrometer-level spatial resolution.

15.
Zhonghua Bing Li Xue Za Zhi ; 51(1): 3-6, 2022 Jan 08.
Artigo em Chinês | MEDLINE | ID: mdl-34979745

RESUMO

With the technological progresses and applications of human genome sequencing, bioinformatics analysis and data mining, and molecular pathology and artificial intelligence-assisted pathological diagnosis, the development of clinical medicine is moving towards the era of precision diagnosis and treatment. In the context of this era, the traditional diagnostic pathology is facing unprecedented opportunities and challenges in our history and is striving towards the "next-generation diagnostic pathology" (NGDP). NGDP is based on histomorphology and clinical data, and characterized by the combination of molecular detection and bioinformatics analysis, intelligent sampling and process quality control, intelligent diagnosis and remote consultation, lesion visualization and "non-invasive" pathology as well as other innovative cutting edge interdisciplinary technologies. The NGDP reports will include the results from multi-omics and cross-scale integrated diagnosis for final diagnosis. NGDP will also be applied for predicting disease progression and outcomes, and determining optional therapeutics as well as assessing treatment responses, so that a novel "golden standard" of disease diagnosis can be established. In the near fature, it is necessary to stimulate the innovative vitality of pathology disciplines, accelerate the maturity and application for NGDP, update the theory and technical system of pathology, and perform its important applicable role in the prevention, diagnosis, treatment of diseases so that the futher development of clinical medicine will be promoted and the strategy for maintenance of being healthy in China will be served.


Assuntos
Inteligência Artificial , Biologia Computacional , China , Humanos , Patologia Molecular
16.
Rev Sci Instrum ; 92(9): 093904, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34598494

RESUMO

A novel high-resolution x-ray spectrometer for point-like emission sources has been developed using a crystal shape having both a variable major and a variable minor radius of curvature. This variable-radii sinusoidal spiral spectrometer (VR-Spiral) allows three common spectrometer design goals to be achieved simultaneously: 1. reduction of aberrations and improved spectral (energy) resolution, 2. reduction of source size broadening, and 3. use of large crystals to improve total throughput. The VR-Spiral concept and its application to practical spectrometer design are described in detail. This concept is then used to design a spectrometer for an extreme extended x-ray absorption fine structure experiment at the National Ignition Facility looking at the Pb L3 absorption edge at 13.0352 keV. The expected performance of this VR-Spiral spectrometer, both in terms of energy resolution and spatial resolution, is evaluated through the use of a newly developed raytracing tool, xicsrt. Finally, the expected performance of the VR-Spiral concept is compared to that of spectrometers based on conventional toroidal and variable-radii toroidal crystal geometries showing a greatly improved energy resolution.

17.
Phys Rev Lett ; 127(15): 155002, 2021 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-34678005

RESUMO

The study of high-velocity particle-laden flow interactions is of importance for the understanding of a wide range of natural phenomena, ranging from planetary formation to cloud interactions. Experimental observations of particle dynamics are sparse given the difficulty of generating high-velocity flows of many particles. Ejecta microjets are micron-scale jets formed by strong shocks interacting with imprinted surfaces to generate particle plumes traveling at several kilometers per second. As such, the interaction of two ejecta microjets provides a novel experimental methodology to study interacting particle streams. In this Letter, we report the first time sequences of x-ray radiography images of two interacting tin ejecta microjets taken on a platform designed for the OMEGA Extended Performance (OMEGA EP) laser. We observe that the microjets pass through each other unattenuated for the case of 11.7±3.2 GPa shock pressures and jet velocities of 2.2±0.5 km/s but show strong interaction dynamics for 116.0±6.1 GPa shock pressures and jet velocities of 6.5±0.5 km/s. We find that radiation-hydrodynamic simulations of the experiments are able to capture many aspects of the collisional behavior, such as the attenuation of jet velocity in the direction of propagation, but are unable to match the full spread of the strongly interacting cloud.

18.
ACS Appl Mater Interfaces ; 13(40): 47972-47986, 2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-34597505

RESUMO

In this work, we encapsulated Fe3O4@SiO2@Ag (MS-Ag), a bifunctional magnetic silver core-shell structure, with an outer mesoporous silica (mS) shell to form an Fe3O4@SiO2@Ag@mSiO2 (MS-Ag-mS) nanocomposite using a cationic CTAB (cetyltrimethylammonium bromide) micelle templating strategy. The mS shell acts as protection to slow down the oxidation and detachment of the AgNPs and incorporates channels to control the release of antimicrobial Ag+ ions. Results of TEM, STEM, HRSEM, EDS, BET, and FTIR showed the successful formation of the mS shells on MS-Ag aggregates 50-400 nm in size with highly uniform pores ∼4 nm in diameter that were separated by silica walls ∼2 nm thick. Additionally, the mS shell thickness was tuned to demonstrate controlled Ag+ release; an increase in shell thickness resulted in an increased path length required for Ag+ ions to travel out of the shell, reducing MS-Ag-mS' ability to inhibit E. coli growth as illustrated by the inhibition zone results. Through a shaking test, the MS-Ag-mS nanocomposite was shown to eradicate 99.99+% of a suspension of E. coli at 1 × 106 CFU/mL with a silver release of less than 0.1 ppb, well under the EPA recommendation of 0.1 ppm. This high biocidal efficiency with minimal silver leach is ascribed to the nanocomposite's mS shell surface characteristics, including having hydroxyl groups and possessing a high degree of structural periodicity at the nanoscale or "smoothness" that encourages association with bacteria and retains high Ag+ concentration on its surface and in its close proximity. Furthermore, the nanocomposite demonstrated consistent antimicrobial performance and silver release levels over multiple repeated uses (after being recovered magnetically because of the oxidation-resistant silica-coated magnetic Fe3O4 core). It also proved effective at killing all microbes from Long Island Sound surface water. The described MS-Ag-mS nanocomposite is highly synergistic, easy to prepare, and readily recoverable and reusable and offers structural tunability affecting the bioavailability of Ag+, making it excellent for water disinfection that will find wide applications.

20.
Rev Sci Instrum ; 92(5): 053102, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243250

RESUMO

We report the development of a high-resolution spectrometer for extended x-ray absorption fine structure (EXAFS) studies of materials under extreme conditions. A curved crystal and detector in the spectrometer are replaceable such that a single body is employed to perform EXAFS measurements at different x-ray energy intervals of interest. Two configurations have been implemented using toroidal crystals with Ge 311 reflection set to provide EXAFS at the Cu K-edge (energy range 8.9-9.8 keV) and Ge 400 reflection set to provide EXAFS at the Ta L3-edge (9.8-10.7 keV). Key performance characteristics of the spectrometer were found to be consistent with design parameters. The data generated at the National Ignition Facility have shown an ≃3 eV spectral resolution for the Cu K-edge configuration and ≃6 eV for the Ta L3-edge configuration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...